Language: Chinese    English

GAS VALVE

  • 120108 GAS VALVE ASSEMBLY
120108 GAS VALVE ASSEMBLY

120108 GAS VALVE ASSEMBLY

  • ITEM NO. 120108


    GAS VALVE ASSEMBLY

    COIL VOLTAGE RATING:12VDC@0.48AMPS
    PULL IN VOLTAGE:9.2 VOLTS MAXIMUM
    DROP OUT VOLTAGE:0.7 VOLTS MINIMUN
    REGULATOR SETTING:10.5"W.C±.0.3@12,000BTU & 14"W.C. INLET PRESSURE
    RECOMMENDED MAXIUMUM TORQUE ON INLET AND OUTLET OPENINGS 30 IN/LBS
    OPERATIONAL IN ANY POSITION SHOWN INCOMING TESTING
    ALLOWABLE LEAKAGE RATED @2" TO 14"W.C.
    INLET TEST PRESSURE:
    EXTERNAL:50㏄ PER HOUR MAXIMUM
    INTERNAL:100㏄ PER HOUR MAXIMUM